本文已于2026年3月在线发表于Journal of Nuclear Medicine and Molecular Imaging杂志。
文章链接(Article Link):https://mednexus.org/doi/epdf/10.65457/JNMMI-2026-0010
引用本文:Wang Y, Wang L, Sun X, Han K, Zhang Z, Fang W. First human validation of rapid myocardial perfusion imaging and quantification using 99mTc-Teboroxime CZT-SPECT: A feasibility study. J Nucl Med Mol Imaging 2026; XXX: XX–XX. doi: 10.65457/JNMMI-2026-0010
How to cite this article: Wang Y, Wang L, Sun X, Han K, Zhang Z, Fang W. First human validation of rapid myocardial perfusion imaging and quantification using 99mTc-Teboroxime CZT-SPECT: A feasibility study. J Nucl Med Mol Imaging 2026; XXX: XX–XX. doi: 10.65457/JNMMI-2026-0010
冠心病的早筛、精准评估一直是心血管诊疗的核心难题。传统心肌灌注显像存在采集时间长、显像剂代谢快、定量精度不足等瓶颈,难以满足临床高效诊断需求。阜外医院团队在国际上首次探讨99mTc-Teboroxime CZT-SPECT 快速心肌灌注显像与定量分析的临床研究,为冠心病无创、快速、精准诊断探索新方法。
此项研究将高初始摄取率的99mTc-Teboroxime与超高灵敏度CZT-SPECT相机结合,力图解决传统显像技术的局限性。99mTc-Teboroxime具备首过提取率高、心肌摄取与血流线性相关的优势,但因心肌清除快、肝脏干扰强,长期难以临床应用。而CZT-SPECT检测效率是传统设备的4-7倍,可在5分钟内完成快速动态采集,更加适配显像剂的快速代谢特性,实现“快摄快采、清晰成像”。
This study reports the first human validation of rapid myocardial perfusion imaging (MPI) and myocardial blood flow (MBF) quantification using 99mTc-Teboroxime with CZT-SPECT in patients with coronary artery disease (CAD).
本次研究纳入45例疑似或确诊冠心病患者,结果显示:该技术在注射后5分钟即可获得最优心肌图像,与临床金标准99mTc-MIBI诊断一致性极佳(Kappa=0.75),且能检出更显著的缺血节段,灵敏度更高。同时,实现心肌血流量(MBF)与心肌灌注储备(MPR)精准定量,正常组心肌灌注储备达2.03,显著高于异常组的1.51,可直观反映冠脉狭窄程度与心肌缺血状态。
与传统技术相比,该方案采集时间更短、患者舒适度更高、诊断信息更全,既能快速完成静息+负荷显像,又能提供定量血流参数,实现“定性+定量” 双维度评估。在严重冠脉狭窄患者中,诊断灵敏度达80%,为缺血判断、危险分层、治疗决策提供可靠依据。
此项成果首次在人体探讨了99mTc-Teboroxime CZT-SPECT的临床可行性,为今后快速定量心肌灌注显像新技术及新药物的研发提供了重要的参照。未来SPECT心肌血流定量分析技术将更广泛应用于冠心病筛查、胸痛鉴别、术前评估、术后随访等,显著提升诊疗效率,推动心血管影像迈向 “无创、快速、精准、定量” 的新时代。
Forty-five patients underwent one-day rest-stress dynamic scans. 99mTc-Teboroxime showed rapid myocardial uptake and peak uptake at 3 minutes, with optimal imaging within 5 minutes post-injection. Semi-quantitative analysis yielded excellent agreement with 99mTc-MIBI (Kappa=0.75), while detecting more pronounced ischemic segments. Quantitative MBF revealed significantly higher stress K1 and myocardial perfusion reserve (MPR) in normal myocardium than in abnormal segments.
Significance:CZT-SPECT overcomes the rapid washout limitation of 99mTc-Teboroxime, enabling fast, high-quality MPI and reliable MBF quantification. This approach improves imaging efficiency and diagnostic precision, offering a promising tool for clinical CAD evaluation.



作者团队
通讯作者:方纬
中国医学科学院阜外医院医学影像中心副主任、核医学科主任,主任医师,博士生导师。国家心血管病专家委员会心血管影像专业委员会副主任委员、中国核学会核医学分会副理事长、中国医学影像技术研究会核医学分会副主任委员等职。从事心血管核医学临床工作三十余年,在创新药物及技术研发领域成果显著。以第一或通讯作者在《Journal of Nuclear Medicine》等国际权威期刊发表SCI论文40余篇,获国家发明专利授权17项,省部级科技奖励6项。
第一作者:王雅雯
中国医学科学院阜外医院核医学科副主任医师,北京协和医学院影像医学与核医学专业博士。主要从事心血管核医学的临床诊疗与科研工作。近五年聚焦于心血管炎症及肿瘤的核素显像研究,同时开展心肌血流定量科研工作。以第一作者在核心期刊及SCI收录期刊发表学术论文十余篇,参与中国医学科学院及国家自然科学基金项目3项、临床试验项目6项。